Mass spectrometry instrumentation
Agilent 6890/5973 Semivolatiles
- Gas Chromatograph Electron Impact Quadrupole mass analyzer system with nominal mass resolution
- Scan range from 10-800 m/z with NIST database for EI spectra searching
- Typically fitted with 5MS column
- Optional Liquid injection Autosampler for 200 samples
Agilent 6890/5973 Volatiles
- Gas Chromatograph Electron Impact Quadrupole mass analyzer system with nominal mass resolution
- Scan range from 10-800 m/z with NIST database for EI spectra searching
- Typically fitted with Volatiles or Wax column
- Optional Liquid injection Autosampler for 200 samples
Agilent 7700x ICP-MS
- Metals analysis
- Mid ppt to low ppb detection range
- Option to detect in four different gas modes to gain optimum detection of multiple metals or interferences in a sample
- Autosampler can hold 21, 50 mL falcon tubes and 180, 15 mL falcon tubes
Agilent 8900x Triple Quadrupole ICP-MS
- Tandem mass spectrometer for elemental analysis expanded to difficult elements
- Collision reaction cell for resolving spectral interferences
- Mid ppt to low ppb detection range
- Autosampler can hold 21 50-mL falcon tubes and 180 15-mL falcon tubes
Bruker timsTOF Pro 2
- Trapped ion mobility spectrometry for gas phase separation of ions with similar m/z ratio but different collisional cross-sections
- Parallel Accumulation Serial Fragmentation allows the TIMS to separate and isolate ions before MS/MS analysis to give higher sensitivity MS2 data collection
- UPLC and nano ESI TOF analysis up to 30,000 m/z (MS2 under 6,000 m/z)
CEM MARS 6 Microwave Digestion System
- Nitric acid digestion of up to 40 samples for ICP-MS analysis
- Sample types for digestion: plants, vitamins, foods, a variety of environmental samples
Metrohm 940 Professional IC Vario Two /SeS
- Ion chromatograph with conductivity detector or optional ICP-MS detection
- Trace analysis for anions and cations
- 148 sample autosampler for 500 µL to 500 mL
Shimadzu 8040 LC-Triple Quadrupole MS with PDA and fluorescence detection
- Nexera X2 LC-30AD UHPLC system with a binary solvent system
- ESI triple quadrupole mass spectrometer
- SPD-M30A diode array detector
- RF-20A XS fluorescence detector
- Quantitative analysis or structural elucidation of small molecules
- Mid ppt to low ppb detection limits
- Mass range: 50 to 2000 Da
- Temperature-controlled autosampler holds 324, 2 mL RAM vials
- Column oven
- Acquired through Shimadzu Grant
Thermo LTQ Orbitrap XL
- LC with direct injection for routine walk-up HRMS analysis by ESI or APCI
- Hybrid Orbitrap capable of DDA, DIA and HRMSn analysis for simultaneous MS/MS analysis of compounds up to 4,000 m/z
Thermo Orbitrap Exploris
- Vanquish Binary UPLC with ESI-Q-Orbitrap
- Thermo CTC PAL Equan UPLC with Dual Gradient pump and switching valves to facilitate comprehensive 2D LC, LC x Land high throughput dual column overlapped injections
- Easy-nanoLC 1200 for low sample loading and higher sensitivity in cell digests
- Capable of HRMS and HRMSMS analysis with high speed and less than 2 ppm error over chromatographic time scales
- Limited to mass range 50–3000 m/z up to 120,000 Resolution, top 4 DDA analysis and up 6 bin DIA
Thermo Scientific Altis LC-Triple Quadrupole MS
- UltiMate 3000 UHPLC System with a binary solvent system that allows four different mobile phases, but only two at a time
- TSQ Altis ESI triple quadrupole mass spectrometer
- Online concentration capabilities
- Online concentration detection range in low ppt
- Standard detection range mid ppt to low ppb
- Mass range: 5 to 2000 Da
- Temperature-controlled autosampler holds 162, 2 mL RAM vials and 30, 10 mL vials and column oven
- Run by laboratory staff only and primarily used for large projects
Thermo Scientific LTQ XL Linear Ion Trap Mass Spectrometer
- UPLC ESI/APCI-MSn system with UV detector
- Resolution can be selected for widths ~2 Da, 0.6 Da, 0.2 Da, 0.1 Da depending on scan rate
- The autosampler can hold 96 samples
Thermo TSQ9610 GC-MS/MS
- Gas Chromatograph Advanced Electron Impact triple Quadrupole mass analyzer system with nominal mass resolution
- Scan range from 10 – 800 m/z with NIST database for EI spectra searching
- Second-stage collision cell allows for enhanced selectivity in quantitative analysis
- The RSH autosampler can automatically run headspace, in tube extraction, SPME or liquid injection from 300 x 2 mL or 90 x 10 mL – 20 mL vials